12.6. AI-900RS Substation Interface Card Connection
12.6.1. Substation and AI-900RS connection
The AI-900RS can be interfaced with up to 16 substations.
[Connection]
Use a 2-core shield cable to connect the substation to the AI-900RS. Refer to the following table for the
maximum recommended cable length between the two.
Cable type AWG24 (0.52 mm) AWG22 (0.65 mm) AWG20 (0.82 mm)
Distance 0.5 km 0.8 km 1.3 km
Connect as shown below.
Connection of the AI-RS150/-RS160/-RS170/-RS180 to the AI-900RS
AI-RS150, AI-RS160,
AI-RS170 or AI-RS180
To line A (orange)
To line B (brown)
To line C (black)
2-core shielded cable
2-core shielded cable
AI-900RS
CN1
CN2
CN3
CN4
Line 1
Line 2
Line 5
Line 6
Line 9
Line 10
Line 13
Line 14
Line 3
Line 4
Line 7
Line 8
Line 11
Line 12
Line 15
Line 16
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
Front view of
the circuit board
Note
The cables coming from the substations are bared at their ends.